Battery Powered Liquid Flow Meter

Battery Powered Liquid Flow Meter

Product Description

This version of ultrasonic liquid flow meters is designed for autonomous operation from integrated battery for more than 10 years. Aimed mainly at flow measurement and monitoring of potable water and wastewater in municipal applications, the meter has a flanged inline section compliant with the applicable standards and additional features like flooding sensor, data transmission via remote external modem and temperature monitoring and logging.

Gallery

The models LFA 101 (single channel
version) and LFA 202 are inline
ultrasonic flow meter for filled liquid
pipelines for applications like flow
monitoring and custody transfer for filled
liquid pipelines. The meter complies with
requirements of EN ISO 4064.

The flow meter is powered by a built-in
lithium battery with a nominal voltage of
3.6 V. The maximum battery capacity is
not less than 19 Ah. Battery life is at
least 10 years.

The models LFA 101 (single channel version) and LFA 202 are inline ultrasonic flow meter for filled liquid pipelines for applications like flow monitoring and custody transfer for filled liquid pipelines. The meter complies with requirements of EN ISO 4064.

The flow meter is powered by a built-in lithium battery with a nominal voltage of 3.6 V. The maximum battery capacity is not less than 19 Ah. Battery life is at least 10 years.

The meter automatically creates and stores in its non-volatile memory the following logs for measured parameters (flow rate, accumulated flow, medium pressure and temperature)
1. Hourly – for each previous hour (4096 records);
2. Daily – for each previous day (2048 records);
3. Monthly – for each previous month (256 records).
4. Per minute – for each previous minute (4096 records);

The flow meter also records in separate archives “Alarms and Errors” (2048 records);
As well as “Interventions”, i.e. configuration changes (2048 records).

Operational (per second) logs (86,400 records) are formed on external media, in
the mode of continuous transmission via RS485 ports. In this log, the flow meter calculates
and records the operating time, the time of partial incapacity, as well as the time of
complete incapacity.

In case of power failure, the logs remain intact for not less than 100 years

1/ Line Sizes : DN 25; 50; 80; 100; 125; 150; 200;250; 300; 500 (larger sizes up to 1500 mm under order)
2/ Flow speed range : 0.4 to 12 m/s
3/ Line pressure range : 1 MPa; 1.6 MPa; 2.5 MPa
4/ Ambient conditions : Temperature -25 to +60 deg C, Relative Humidity up to 100%
5/ Pressure drop : not more than 10 KPa
6/ Accuracy : Class I (1% ##### 2% ####)
7/ Accuracy of time measurement : not less than +/-2 s per 24 hours
8/ Outputs : two RS485 ports (one of them optical; compliant to IEC 62056-21) for
connection to DCS, configuration, data transmission etc.
9/ Integral / external pressure and temperature measurement and logging
10/ local display : Graphic LCD
11/ Integral submersion sensor
12/ Ingress protection level IP 67 (SS Inline section); IP 68 (Polymer enclosure of Electronics
Unit)
13/ Process connections : Threaded (DN 50 to DN 100); Flanged (All sizes)
14/ Available with integrated as well as remote Electronics Unit
15/ optional AMR features (GPRS / NBIoT)